resolution, sampling rate
detection zones
for different objects:
The dark grey areas are determined
with a thin round bar (10 mm dia.)
and indicate the typical operating range
of a sensor. In order to obtain the light grey
areas, a plate (100 x 100 mm) is introduced
into the beam spread from the side.
In doing so, the optimum angle between
plate and sensor is always employed.
This therefore indicates the maximum
detection zone of the sensor.
It is not possible to evaluate ultrasonic
reflections outside this area.
±1% (temperature drift internally compensated)
15 - 30 V DC, reverse polarity protection
no-load current consumption
ultrasonic transducer: polyurethane foam,
epoxy resin with glass content
class of protection to EN 60 529
pulse width synchroniszation signal t
i
LED yellow (object in the window)
repetition rate synchronization signal t
p
time delay before availability
R
L
≤ 500 Ω, rising/falling characteristic
R
L
≥ 100 kΩ, short circuit proof,
rising/falling characteristic
1 analogue output
1
2
4
3
+U
B
-U
B
Com
U
R
L
U | I
8 cm 4 cm 0 cm 4 cm 8 cm
0 cm
4 cm
8 cm
12 cm
16 cm
20 cm
24 cm
Round bar
Plate
microsonic
GmbH • Hauert 16 • D-44227 Dortmund • Tel: +49 2 31 / 97 51 51-0 • Fax: +49 2 31 / 97 51 51-51 • E-Mail: [email protected] • www.microsonic.de The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.MV-DO-142528-444239