Sensor adjustment with Teach-in procedure
Adjust detect point D1
Place object at position
Adjust window mode D1
Place object at position
Adjust two-way reflectiv
barrier D1
Place reflector at position
Set NOC/NCC D1
Adjust detect point D2
Place object at position
Adjust window mode D2
Place object at position
Adjust two-way reflectiv
barrier D2
Place reflector at position
Set NOC/NCC D2
Connect Com to +U
B
until both
LEDs flash simultaneously
(ca. 3 s)
Both LEDs:
flash
mutually
Connect Com to +U
B
for about 1 s
Connect Com to +U
B
until both
LEDs flash simultaneously
(ca. 3 s)
Both LEDs:
Place object at position
flash
mutually
Beide LEDs:
Connect Com to +U
B
for about 1 s
blinken
wechselseitig
Connect Com to +U
B
until both
LEDs flash simultaneously
(ca. 3 s)
Both LEDs:
flash
mutually
Connect Com to +U
B
until both
LEDs flash mutually
(ca. 13 s)
LED D1:
LED D2:
Connect Com to +U
B
for about 10 s
To change output characteristic
connect Com to +U
B
for about 1 s
Wait for 10 s
on: NOC
off: NCC
flashes
Connect Com to -U
B
until both
LEDs flash simultaneously
(ca. 3 s)
Both LEDs:
flash
mutually
Connect Com to -U
B
for about 1 s
Connect Com to -U
B
until both
LEDs flash simultaneously
(ca. 3 s)
Both LEDs:
Place object at position
flash
mutually
Beide LEDs:
Connect Com to -U
B
for about 1 s
blinken
wechselseitig
Connect Com to -U
B
until both
LEDs flash simultaneously
(ca. 3 s)
Both LEDs:
flash
mutually
Connect Com to -U
B
until both
LEDs flash mutually
(ca. 13 s)
LED D2:
LED D1:
Connect Com to -U
B
for about 10 s
To change output characteristic
connect Com to -U
B
for about 1 s
Wait for 10 s
on: NOC
off: NCC
flashes
Normal mode operation
Normal mode operation
1
1
2
1
85 %
1
1
2
1
85 %
Ultrasonic Sensors
1
3
colour
+U
B
-U
B
brown
blue
4
2
5
D2
D1
black
white
Com. grey
1
5
2
34
>10 cm
>30 cm
>1,0 m
>1,7 m
>60 cm
>5,4 m
A
B
*B7300*
Set switched output D1
Set switched output D2
Lock Teach-in & factory setting
Activate/deactivate
Teach-in
Reset to factory
setting
Turn supply voltage OFF
While Com is connected
to -U
B
turn on
power suply
Turn supply voltage OFF
While Com is connected
to -U
B
turn on
power suply
Keep Com connected to
-U
B
until both LEDs flash
simultaneously
(ca. 3 s)
LED D1:
LED D2:
on: Teach-in
activated
off: Teach-in
deactivated
flashes
To activate or
deactivate Teach-in
connect Com to -U
B
for
about 1 s
Wait for 10 s
Keep Com connected to
-U
B
until both LEDs
stop flashing
(ca. 13 s)
Normal mode operation
Vista de pagina 0
1 2 3

Indice de contenidos

Pagina 1 - Instruction manual

Sensor adjustment with Teach-in procedureAdjust detect point D1Place object at position  Adjust window mode D1Place object at position  Adjust two-w

Pagina 2 - Technical data

Technical dataBlind zoneOperating rangeMaximum rangeAngle of beam spread0 to 30 mm250 mm0 to 65 mm350 mm350 mmSee detection zone600 mmSee detection zo

Pagina 3

microsonic GmbH • Hauert 16 • D-44227 Dortmund • Tel: +49 2 31 / 97 51 51-0 • Fax: +49 2 31 / 97 51 51-51 • E-Mail: [email protected] • www.microsoni